Description

Configuration register 0 for channel 2

Fields

TIMER_SEL

This field is used to select one of timers for channel %s.

0: select timer0, 1: select timer1, 2: select timer2, 3: select timer3

SIG_OUT_EN

Set this bit to enable signal output on channel %s.

IDLE_LV

This bit is used to control the output value when channel %s is inactive (when LEDC_SIG_OUT_EN_CH%s is 0).

PARA_UP

This bit is used to update LEDC_HPOINT_CH%s, LEDC_DUTY_START_CH%s, LEDC_SIG_OUT_EN_CH%s, LEDC_TIMER_SEL_CH%s, LEDC_DUTY_NUM_CH%s, LEDC_DUTY_CYCLE_CH%s, LEDC_DUTY_SCALE_CH%s, LEDC_DUTY_INC_CH%s, and LEDC_OVF_CNT_EN_CH%s fields for channel %s, and will be automatically cleared by hardware.

OVF_NUM

This register is used to configure the maximum times of overflow minus 1.

The LEDC_OVF_CNT_CH%s_INT interrupt will be triggered when channel %s overflows for (LEDC_OVF_NUM_CH%s + 1) times.

OVF_CNT_EN

This bit is used to enable the ovf_cnt of channel %s.

OVF_CNT_RESET

Set this bit to reset the ovf_cnt of channel %s.